SONY CORPORATION
SDT-2000, SDT-4000
Device Type |
Tape Drive |
Interface |
SCSI-2 |
Format |
DDS, DDS-DC, DCLZ |
Sustained Transfer Rate |
183 KBPS (SDT-2000) 183-366 KBPS (SDT-4000) |
Size |
3.5 in. half height |
View |
Top |
USER CONFIGURABLE SETTINGS | |||
Setting |
Label |
Position | |
» |
Data compression disabled |
JP1/Pins 7 & 8 |
Closed |
Data compression enabled |
JP1/Pins 7 & 8 |
Open | |
» |
Parity enabled |
JP1/Pins 9 & 10 |
Closed |
Parity disabled |
JP1/Pins 9 & 10 |
Open | |
» |
Factory configured - do not alter. |
JP1/Pins 11 & 12 |
Unidentified |
» |
Terminator enabled |
JP1/Pins 13 & 14 |
Closed |
Terminator disabled |
JP1/Pins 13 & 14 |
Open |
DRIVE SELECT ID | |||
Drive ID |
JP1/Pins 1 & 2 |
JP1/Pins 3 & 4 |
JP1/Pins 5 & 6 |
0 |
Open |
Open |
Open |
1 |
Open |
Open |
Closed |
2 |
Open |
Closed |
Open |
3 |
Open |
Closed |
Closed |
4 |
Closed |
Open |
Open |
5 |
Closed |
Open |
Closed |
6 |
Closed |
Closed |
Open |
7 |
Closed |
Closed |
Closed |
TERMINATION POWER SELECTION | ||
Setting |
JP1/Pins 15 & 16 | |
» |
TERMPWR supplied by drive |
Closed |
TERMPWR supplied by SCSI interface to drive |
Open |
MANUFACTURERS RECOMMENED MEDIA | |||
Drive |
Tape |
Capacity Without Compression |
Capacity With Compression |
SDT-2000 |
DDS 90 meter |
2.0 GB |
Unidentified |
SDT-4000 |
DDS (DCLZ) 90 meter |
2.0-4.0 GB |
4.0-8.0 GB |
DIAGNOSTIC LED(S) | |||||
LEDs |
Functions | ||||
LED1 |
LED2 |
LED3 |
Activity |
Cartridge |
Other |
Off |
Off |
Off |
None |
None |
None |
On |
Off |
Off |
SCSI |
None |
None |
Flashing 1 |
Flashing 1 |
Off |
Loading/Unloading |
None | |
Flashing 1 |
Flashing 1 |
On |
Loading/Unloading |
Write Protected | |
Off |
On |
Flashing 1 |
None |
Loaded |
Cleaning Tape at EOM |
Off |
On |
Off |
None |
Loaded |
None |
On |
On |
Off |
SCSI |
Loaded |
None |
Flashing 1 |
On |
Off |
SCSI/Drive |
Loaded |
None |
Unidentified |
On |
On |
X |
Loaded |
Write Protected |
Unidentified |
Flashing 2 |
Unidentified |
X |
Loaded |
Error Rate Warning |
Flashing 2 |
Unidentified |
Unidentified |
X |
X |
Humidity Warning |
Unidentified |
Unidentified |
Flashing 2 |
X |
X |
Cleaning Request |
Unidentified |
Unidentified |
Flashing 3 |
X |
X |
Drive Mechanism Failure |
Unidentified |
Unidentified |
Flashing 4 |
X |
X |
Drive Circuitry Failure |
Flashing 3 |
Unidentified |
Unidentified |
X |
X |
Waiting for Reset |
Unidentified |
Flashing 3 |
Unidentified |
X |
X |
Waiting for Eject |
Note: 1 LED flashes at 0.25 seconds on/0.25 seconds off. 2 LED flashes at 3.5 seconds on/0.25 seconds off. 3 LED emits a continuous pulse at 0.25 seconds on. 4 LED emits a continuous double pulse at 0.25 seconds on. ‘X’ means not applicable. |