EAGLE TECHNOLOGY
RX-NET II
NIC Type |
ARCnet |
Transfer Rate |
2.5Mbps |
Data Bus |
8-bit ISA |
Topology |
Star |
Wiring Type |
RG-62A/U 93ohm coaxial |
Boot ROM |
Available |
NODE ADDRESS |
||||||||
Node |
SW3/1 |
SW3/2 |
SW3/3 |
SW3/4 |
SW3/5 |
SW3/6 |
SW3/7 |
SW3/8 |
0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
Off |
On |
On |
On |
On |
On |
On |
On |
2 |
On |
Off |
On |
On |
On |
On |
On |
On |
3 |
Off |
Off |
On |
On |
On |
On |
On |
On |
4 |
On |
On |
Off |
On |
On |
On |
On |
On |
251 |
Off |
Off |
On |
Off |
Off |
Off |
Off |
Off |
252 |
On |
On |
Off |
Off |
Off |
Off |
Off |
Off |
253 |
Off |
On |
Off |
Off |
Off |
Off |
Off |
Off |
254 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
255 |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Note:Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, Off=1) |
INTERRUPT REQUEST |
|||||
IRQ |
JP1 |
JP2 |
JP3 |
JP4 |
JP5 |
2 |
Closed |
Open |
Open |
Open |
Open |
3 |
Open |
Closed |
Open |
Open |
Open |
4 |
Open |
Open |
Closed |
Open |
Open |
5 |
Open |
Open |
Open |
Closed |
Open |
7 |
Open |
Open |
Open |
Open |
Closed |
I/O BASE ADDRESS |
||||||
Address |
SW2/1 |
SW2/2 |
SW2/3 |
SW2/4 |
SW2/5 |
SW2/6 |
200h |
Off |
On |
On |
On |
On |
On |
250h |
Off |
On |
On |
Off |
On |
Off |
2A0h |
Off |
On |
Off |
On |
Off |
On |
2E0h |
Off |
On |
Off |
Off |
Off |
On |
2F0h |
Off |
On |
Off |
Off |
Off |
Off |
300h |
Off |
Off |
On |
On |
On |
On |
350h |
Off |
Off |
On |
Off |
On |
Off |
3E0h |
Off |
Off |
Off |
Off |
Off |
Off |
BUFFER ADDRESS |
||||||
Address |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 |
SW1/5 |
SW1/6 |
C0000h |
Off |
Off |
On |
On |
On |
On |
C4000h |
Off |
Off |
On |
On |
On |
Off |
C8000h |
Off |
Off |
On |
On |
On |
On |
CC000h |
Off |
Off |
On |
On |
Off |
Off |
D0000h |
Off |
Off |
On |
Off |
On |
On |
D4000h |
Off |
Off |
On |
Off |
On |
On |
D8000h |
Off |
Off |
On |
Off |
Off |
On |
DC000h |
Off |
Off |
On |
Off |
Off |
Off |
E0000h |
Off |
Off |
Off |
On |
On |
On |
FACTORY CONFIGURED SETTINGS |
|
Jumper/Switch |
Setting |
JP6 |
N/A |
SW1/7 |
On |
SW1/8 |
On |