HwMuseum | Index

DIAMOND FLOWER, INC.

NET-760ECT

Card Type

Network Interface Card

NIC Type

Ethernet

Maximum Onboard Memory

16KB

Boot ROM

Available

Network Transfer Rate

10Mbps

Topology

Linear Bus, Star

Wiring Type

Unshielded twisted pair

AUI transceiver via DB-15 port

RG-58A/U 50ohm coaxial

Data Bus

16-bit ISA

CONNECTIONS

Function

Label

Function

Label

RJ-45 connector

CN1

RG-58A/U connector

CN3

AUI transceiver via DB-15 port

CN2

   

SOFTWARE/JUMPER SELECT

Setting

JP2

JP3

JP4

»

Card is software configurable

Open

Open

Closed

 

Card is jumper configurable

Closed

Closed

Open

Note: If card is set to "software configurable", jumper cab on IRQ block should be removed.

INTERRUPT SELECTION (JP6)

IRQ

A

B

C

D

E

F

G

H

 

2

Closed

Open

Open

Open

Open

Open

Open

Open

»

3

Open

Closed

Open

Open

Open

Open

Open

Open

 

4

Open

Open

Closed

Open

Open

Open

Open

Open

 

5

Open

Open

Open

Closed

Open

Open

Open

Open

 

10

Open

Open

Open

Open

Closed

Open

Open

Open

 

11

Open

Open

Open

Open

Open

Closed

Open

Open

 

12

Open

Open

Open

Open

Open

Open

Closed

Open

 

15

Open

Open

Open

Open

Open

Open

Open

Closed

ROM ADDRESS SELECTION

Address

J1

J2

J3

J4

»

Disabled

Open

Open

Open

N/A

 

C0000H

Open

Open

Closed

Open

 

C4000H

Open

Open

Closed

Closed

 

C8000H

Open

Closed

Open

Open

 

CC000H

Open

Closed

Open

Closed

 

D0000H

Open

Closed

Closed

Open

 

D4000H

Open

Closed

Closed

Closed

 

D8000H

Closed

Open

Open

Open

 

DC000H

Closed

Open

Open

Closed

BASE I/O ADDRESS SELECTION

Setting

J5

J6

J7

 

240h

Open

Closed

Open

 

280h

Open

Closed

Closed

 

2C0h

Closed

Open

Open

 

320h

Closed

Open

Closed

»

330h

Open

Open

Open

 

340h

Closed

Closed

Open

 

360h

Closed

Closed

Closed

AT BUS COMPATIBILITY SELECT (JP1)

Setting

A

B

C

»

System compatible w/IBM PC/AT bus

Open

Closed

Closed

 

System not compatible w/IBM PC/AT bus

Closed

Closed

Open

CABLE TYPE SELECTION

Type

JP5

»

BNC/RJ-45 (auto select) enabled

Open

 

AUI enabled

Closed

DIAGNOSTIC LED(S)

LED

Color

Status

Condition

LED1

Green

On

UTP link is good

LED1

Green

Off

UTP link is broken