COMPU-SHACK PRODUCTION, GMBH
CS-ARCNET-KARTE TURBO, CS-ARCNET-KARTE SPECIAL
NIC Type: |
ARCnet |
Transfer Rate: |
2.5Mbps |
Data Bus: |
8-bit ISA |
Topology: |
Linear Bus |
Wiring Type |
RG62A/U 93ohm coaxial |
Boot ROM |
Available |
INTERRUPT SELECT - J2 | ||||||
IRQ |
Jumper A |
Jumper B |
Jumper D |
Jumper D |
Jumper E | |
» |
IRQ2 |
Closed |
Open |
Open |
Open |
Open |
IRQ3 |
Open |
Closed |
Open |
Open |
Open | |
IRQ4 |
Open |
Open |
Closed |
Open |
Open | |
IRQ5 |
Open |
Open |
Open |
Closed |
Open | |
IRQ7 |
Open |
Open |
Open |
Open |
Closed |
RESPONSE TIME-OUTS | |||
Response Time |
J4/jumper A |
J4/jumper B | |
» |
74.7µs |
Open |
Open |
283.4µs |
Closed |
Open | |
561.8µs |
Open |
Closed | |
1118.6µs |
Closed |
Closed |
BOOT ROM | ||
Setting |
S1/1 | |
» |
Disabled |
Off |
Enabled |
On |
I/O ADDRESS | |||||||
Address |
S1/1 |
S1/2 |
S1/3 |
S1/4 |
S1/5 |
S1/6 | |
» |
2E0h |
Off |
On |
Off |
Off |
Off |
On |
200h |
Off |
On |
On |
On |
On |
On | |
210h |
Off |
On |
On |
On |
On |
Off | |
220h |
Off |
On |
On |
On |
Off |
On | |
230h |
Off |
On |
On |
On |
Off |
Off | |
240h |
Off |
On |
On |
Off |
On |
On | |
250h |
Off |
On |
On |
Off |
On |
Off | |
260h |
Off |
On |
On |
Off |
Off |
On | |
270h |
Off |
On |
On |
Off |
Off |
Off | |
280h |
Off |
On |
Off |
On |
On |
On | |
290h |
Off |
On |
Off |
On |
On |
Off | |
2A0h |
Off |
On |
Off |
On |
Off |
On | |
2B0h |
Off |
On |
Off |
On |
Off |
Off | |
2C0h |
Off |
On |
Off |
Off |
On |
On | |
2D0h |
Off |
On |
Off |
Off |
On |
Off | |
2F0h |
Off |
On |
Off |
Off |
Off |
Off | |
300h |
Off |
Off |
On |
On |
On |
On | |
310h |
Off |
Off |
On |
On |
On |
Off | |
320h |
Off |
Off |
On |
On |
Off |
On | |
330h |
Off |
Off |
On |
On |
Off |
Off | |
340h |
Off |
Off |
On |
Off |
On |
On | |
350h |
Off |
Off |
On |
Off |
On |
Off | |
360h |
Off |
Off |
On |
Off |
Off |
On | |
370h |
Off |
Off |
On |
Off |
Off |
Off | |
380h |
Off |
Off |
Off |
On |
On |
On | |
390h |
Off |
Off |
Off |
On |
On |
Off | |
3A0h |
Off |
Off |
Off |
On |
Off |
On | |
3B0h |
Off |
Off |
Off |
On |
Off |
Off | |
3C0h |
Off |
Off |
Off |
Off |
On |
On | |
3D0h |
Off |
Off |
Off |
Off |
On |
Off | |
3E0h |
Off |
Off |
Off |
Off |
Off |
On | |
3F0h |
Off |
Off |
Off |
Off |
Off |
Off |
MEMORY ADDRESS | |||||
Address |
S1/7 |
S1/8 |
S1/9 |
S1/10 | |
» |
D0000h |
On |
Off |
On |
On |
C0000h |
On |
On |
On |
On | |
C4000h |
On |
On |
On |
Off | |
C8000h |
On |
On |
Off |
On | |
CC000h |
On |
On |
Off |
Off | |
D4000h |
On |
Off |
On |
Off | |
D8000h |
On |
Off |
Off |
On | |
DC000h |
On |
Off |
Off |
Off | |
E0000h |
Off |
On |
On |
On | |
E4000h |
Off |
On |
On |
Off | |
E8000h |
Off |
On |
Off |
On | |
EC000h |
Off |
On |
Off |
Off | |
F0000h |
Off |
Off |
On |
On | |
F4000h |
Off |
Off |
On |
Off | |
F8000h |
Off |
Off |
Off |
On | |
FC000h |
Off |
Off |
Off |
Off |
NODE ID NUMBER | ||||||||
ID # |
S2/1 |
S2/2 |
S2/3 |
S2/4 |
S2/5 |
S2/6 |
S2/7 |
S2/8 |
1 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
255 |
On |
On |
On |
On |
On |
On |
On |
On |
Note:Nodes can be numbered from 1 to 255. The switches are a binary representation of the node numbers. When a switch is on, the corresponding bit is set to 1 and has the following decimal value: S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128. |
DIAGNOSTIC LED | |
Status |
Condition |
On |
Data is being transmitted or received |
Off |
Data is not being transmitted or received |