HwMuseum | Index

COMPU-SHACK PRODUCTION, GMBH

CS-ETHERNET-KARTE COMBO (REV. C.1/C.1 PLUS)

NIC Type:

Ethernet

Transfer Rate:

10Mbps

Data Bus:

16-bit ISA

Topology:

Linear Bus

Star

Wiring Type

AUI transceiver via DB-15 port

RG58A/U 50ohm coaxial

Shielded/unshielded twisted pair

Boot ROM

Available

INTERRUPT SELECT - J1

IRQ

A

B

C

D

E

F

G

H

»

IRQ3

Open

Open

Open

Open

Open

Open

Open

Closed

 

IRQ4

Open

Open

Open

Open

Open

Open

Closed

Open

 

IRQ5

Open

Open

Open

Open

Open

Closed

Open

Open

 

IRQ7

Open

Open

Open

Open

Closed

Open

Open

Open

 

IRQ9

Open

Open

Open

Closed

Open

Open

Open

Open

 

IRQ10

Open

Open

Closed

Open

Open

Open

Open

Open

 

IRQ11

Open

Closed

Open

Open

Open

Open

Open

Open

 

IRQ12

Closed

Open

Open

Open

Open

Open

Open

Open

CARD EMULATION - J2

Setting

Jumper A

Jumper B

Jumper C

Jumper D

NE1000 mode

Open

Closed

Open

Open

NE2000 mode

Closed

Open

Open

Open

CS 16KB mode

Open

Open

Closed

Open

CS 64KB mode

Open

Open

Open

Closed

WIRING TYPE SELECT - J5

Setting

Jumper A

jumper B

Jumper C

Jumper D

Jumper E

Jumper F

BNC

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

AUI

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

BOOT ROM INSTALLATION

Setting

J6

J7

»

Install in IBM PC compatible

Pins 2 & 3 closed

Pins 2 &3 closed

 

Install in IBM AT compatible

Pins 1 & 2 closed

Pins 1 & 2 closed

SOFTWARE COMPATIBILITY/BUS SELECT

Setting

J8

NE1000 or NE2000/8-bit PC or AT slot

All pins open

NE2000/8-bit PC or 16-bit AT slot or CS-format/16-bit AT slot

Pins 1 & 3 closed

NE2000/16-bit AT slot

Pins 3 & 4 closed

BNC TYPE

Setting

J9/jumper A

J9/jumper B

»

RG58A/U 50ohm coaxial

Pins 2 & 3 closed

Pins 2 &3 closed

 

RG62A/U 93ohm coaxial

Pins 1 & 2 closed

Pins 1 & 2 closed

WIRING TYPE SELECT - J14

Setting

Jumper A

jumper B

Jumper C

Jumper D

Jumper E

Jumper F

BNC

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

UTP

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

Note:J14 should be set to the BNC setting if J5 is also.

PAL MODES

Setting

J16

PAL P12EATW3/P12EATB3 compatible

Open

PAL P12EATW/P12EATB compatible

Closed

Note: This jumper applies to the CS-Ethernet COMBO Rev. B.4 only.

I/O ADDRESS

Address

SW1/1

SW1/2

SW1/3

SW1/4

»

300h

Off

On

On

On

 

200h

On

On

On

On

 

220h

On

On

On

Off

 

240h

On

On

Off

On

 

260h

On

On

Off

Off

 

280h

On

Off

On

On

 

2A0h

On

Off

On

Off

 

2C0h

On

Off

Off

On

 

2E0h

On

Off

Off

Off

 

320h

Off

On

On

Off

 

340h

Off

On

Off

On

 

360h

Off

On

Off

Off

 

380h

Off

Off

On

On

 

3A0h

Off

Off

On

Off

 

3C0h

Off

Off

Off

On

 

3E0h

Off

Off

Off

Off

BOOT ROM ADDRESS

Address

SW1/5

SW1/6

SW1/7

SW1/8

»

Disabled

N/A

N/A

N/A

Off

 

C0000h

On

On

On

On

 

C4000h

On

On

Off

On

 

C8000h

On

Off

On

On

 

CC000h

On

Off

Off

On

 

D0000h

Off

On

On

On

 

D4000h

Off

On

Off

On

 

D8000h

Off

Off

On

On

 

DC000h

Off

Off

Off

On

DIAGNOSTIC LEDS

LED

Status

Condition

D1

On

Twisted pair network connection is good

D2

On

Twisted pair network connection is broken

D3

On

Collision detected on network

D4

On

Data is being transmitted (UTP connection only)

D5

On

Data is being received (UTP connection only)