HwMuseum | Index

COMPAQ COMPUTER CORPORATION

PROLIANT 2000R

Processor

Pentium

Processor Speed

66/90MHz

Chip Set

Unidentified

Video Chip Set

None

Maximum Onboard Memory

512MB (EDO supported)

Maximum Video Memory

1MB

Cache

256/512KB

BIOS

Unidentified

Dimensions

305mm x 244mm

I/O Options

Unidentified

NPU Options

None

CONNECTIONS

Purpose

Location

Purpose

Location

Proprietary slots

SL1 – SL4

External memory card

SL5

Note: The location and types of I/O options are unidentified.

USER CONFIGURABLE SETTINGS

Function

Label

Position

»

Factory configured - do not alter

SW4/1

On

»

Soft switching mode enabled

SW4/2

On

 

Soft switching mode disabled

SW4/2

Off

»

Keyboard broadcasting mode disabled

SW4/3

Off

 

Keyboard broadcasting mode enabled

SW4/3

On

»

Mouse broadcasting mode disabled

SW4/4

Off

 

Mouse broadcasting mode enabled

SW4/4

On

»

Scan mode enabled

SW4/5

On

 

Scan mode disabled

SW4/5

Off

»

Tiering mode disabled

SW4/6

Off

 

Tiering mode enabled

SW4/6

On

»

Factory configured - do not alter

SW4/7

Unidentified

»

Factory configured - do not alter

SW4/8

Unidentified

DRAM CONFIGURATION

Size

Bank 0

Bank 1

Bank 2

Bank 3

64MB

(4) 4M x 36

None

None

None

128MB

(4) 8M x 36

None

None

None

256MB

(4) 16M x 36

None

None

None

128MB

(4) 4M x 36

(4) 4M x 36

None

None

256MB

(4) 8M x 36

(4) 8M x 36

None

None

256MB

(4) 4M x 36

(4) 4M x 36

(4) 4M x 36

(4) 4M x 36

512MB

(4) 8M x 36

(4) 8M x 36

(4) 8M x 36

(4) 8M x 36

Note: The location of banks 0 & 1 is unidentified. Banks 2 & 3 are located on the memory card.

CACHE CONFIGURATION

Note: The location of the cache is unidentified.

MONITOR SELECTION NOTE

Note: The Proliant 2000R is capable of controlling up to 8 servers, each with their own monitor. To select a monitor type for a specific server, first consult either the 4 or 8 Port Monitor Control Selection Table to determine which switches are used for the configuration.. Then refer to the Server Monitor Selection table to determine the individual switch settings.

4 PORT MONITOR CONTROL SELECTION

Switch

Controlling switches

Server controlled

S1

S1/1 - 4

1

S1

S1/5 - 8

2

S2

S2/1 - 4

3

S2

S2/5 - 8

4

8 PORT MONITOR CONTROL SELECTION

Switch

Controlling switches

Server controlled

S1

S1/1 - 4

1

S1

S1/5 - 8

2

S2

S2/1 - 4

3

S2

S2/5 - 8

4

S3

S3/1 - 4

5

S3

S3/5 - 8

6

S4

S3/1 - 4

7

S4

S3/5 - 8

8

SERVER MONITOR SELECTION

Type

SW1/1 orSW1/5

SW1/2 orSW1/6

SW1/3 orSW1/7

SW1/4 orSW1/8

VGA

Off

Off

On

Off

Monochrome

Off

Off

On

Off

VGA

Off

On

Off

Off

SVGA

Off

On

Off

Off

SVGA- Compaq 430

On

On

Off

On

XVGA – IBM8512

Off

On

Off

Off

XVGA – IBM8513

Off

On

Off

Off

XVGA – IBM8514

On

On

Off

Off

XVGA – IBM8515

On

Off

Off

Off

Note: Each bank of switches must reflect the type of monitor configured on the server.