HwMuseum | Index

IOMEGA CORPORATION

PC2/50, PC2B/50

Data bus:

8-bit ISA

Size:

Half-length, full-height card

Hard drive supported:

None

Floppy drives supported:

Two Bernoulli Box drives

CONNECTIONS

Function

Location

34-pin Bernoulli Box connector - external drive

CN1

50-pin Bernoulli Box connector - internal drive

CN2

USER CONFIGURABLE SETTINGS

Function

Location

Setting

»

DMA channel 3 select

SW3

off

 

DMA channel 1 select

SW3

on

»

DMA enabled

SW4

off

 

PIO (Programmed Input/Ouput) enabled

SW4

on

»

IRQ5 select

SW6

off

 

IRQ7 select

SW6

on

»

Factory configured - do not alter

SW7

off

»

Two 10MB Bernoulli drives in system

SW8

off

 

One 10MB Bernoulli drive in system

SW8

on

PORT ADDRESS SELECTION

Address

SW1

SW2

SW5

»

340h

on

on

off

 

348h

on

on

on

 

350h

off

on

off

 

358h

off

on

on

 

360h

on

off

off

 

368h

on

off

on

 

370h

off

off

off

 

Disabled

off

off

off

ROM ADDRESS SELECTION (PC2B/50 ONLY)

Address

JP1

JP2

JP3

JP4

 

C800:0000h - C800:1FFFh

1 & 2

1 & 2

1 & 2

1 & 2

 

CA00:0000h - CA00:1FFFh

1 & 2

1 & 2

1 & 2

2 & 3

»

CE00:0000h - CE00-1FFFh

1 & 2

1 & 2

2 & 3

2 & 3

 

D000:0000h - D000:1FFFh

1 & 2

2 & 3

1 & 2

1 & 2

 

D200:0000h - D200:1FFFh

1 & 2

2 & 3

1 & 2

2 & 3

 

D400:0000h - D400:1FFFh

1 & 2

2 & 3

2 & 3

1 & 2

 

D600:0000h - D600:1FFFh

1 & 2

2 & 3

2 & 3

2 & 3

 

D800:0000h - D800:1FFFh

2 & 3

1 & 2

1 & 2

1 & 2

 

DA00:0000h - DA00:1FFFh

2 & 3

1 & 2

1 & 2

2 & 3

 

DC00:0000h - DC00:1FFFh

2 & 3

1 & 2

2 & 3

1 & 2

 

DE00:0000h - DE00:1FFFh

2 & 3

1 & 2

2 & 3

2 & 3

 

E000:0000h - E000:1FFFh

2 & 3

2 & 3

1 & 2

1 & 2

 

E200:0000h - E200:1FFFh

2 & 3

2 & 3

1 & 2

2 & 3

 

E400:0000h - E400:1FFFh

2 & 3

2 & 3

2 & 3

1 & 2

 

RAM/ROM disabled

2 & 3

2 & 3

2 & 3

2 & 3

Note: Designated pins should be in the closed position.

MISCELLANEOUS TECHNICAL NOTES

Model PC2/50 is the same as PC2B/50 with the exception of jumper shunts, and RAM and ROM chips. PC2/50 can be upgraded to PC2B/50 by ordering an upgrade kit that includes shunts and chips.